Skip to content

Cybersecurity

CRA guidance: product class and conformity assessment

Commission CRA guidance: product class by core functionality, the conformity assessment path, state of harmonised standards and IEC 62443 versus the CRA.

Published 34 min read

CRACyber Resilience Actconformity assessmentrisk assessmentimportant and critical productsIEC 62443
Contents
  1. The product class decides the conformity assessment procedure
  2. Core functionality and additional functions
  3. OT products: core functionality first
  4. Decision table: product class and conformity assessment path
  5. The IIoT gateway: class and evidence
  6. Class I, harmonised standards and the presumption of conformity
  7. State of harmonised standards as of 25 November 2026
  8. IEC 62443-4-1 and 62443-4-2 against Annex I: our analysis
  9. Risk assessment: an appropriate level instead of risk appetite
  10. External dependencies and components
  11. Product families
  12. Complex systems and older designs
  13. Certificates under the RED and the Machinery Regulation
  14. Checklist of evidence before the conformity assessment
  15. Where we help
  16. Legal basis
  17. Sources

Before 11 December 2027, the manufacturer of an industrial gateway needs to know two things. The first is the conformity assessment procedure the product will go through. The second is the evidence to show a notified body or a market surveillance authority. The class of the product decides the procedure. The risk assessment decides the evidence.

The Commission explained both topics in its guidance C/2026/6013 on the Cyber Resilience Act (CRA). It published the guidance on 27 July 2026, and the Official Journal of the EU followed on 17 November 2026. The guidance states that:

  • the class of a product follows from its core functionality, and a product has only one such core functionality;
  • integrating an important component does not make the whole product important;
  • an important product of class I may follow the internal control procedure when the manufacturer has fully applied a harmonised standard, a common specification or a European cybersecurity certification scheme at assurance level at least “substantial” that covers the risks of the core functionality;
  • residual risk is judged against an appropriate level of cybersecurity, not against the manufacturer’s risk appetite or costs;
  • a product designed before 11 December 2027 may be placed on the market without redesign if the risk assessment shows that its existing safeguards are sufficient.

The guidance is not binding, and only the Court of Justice of the EU interprets the CRA with binding effect. Examples with a number come from the guidance, and examples marked as ours are SEQRED illustrations. This text is not legal advice.

NOTE

Series: Commission guidance on the CRA in practice

  1. Which products the Cyber Resilience Act covers
  2. Vulnerability reporting, known vulnerabilities and testing
  3. Cloud and remote data processing in a product
  4. Open source: manufacturer, steward and contributor
  5. Updates, repairs and the support period
  6. Product class, risk assessment and conformity assessment (this article)

All parts follow the same fictional case: the BG-200 IIoT gateway, whose product card is included in part 1.

NOTE

The IIoT gateway in this part

The core functionality of the BG-200 gateway from the product card in part 1 is collecting, processing and forwarding measurements to the manufacturer’s cloud. This description matches no category in Annexes III and IV, so in our assessment the gateway belongs to the default category and may follow internal control (module A). The packet firewall and the VPN client are additional functions that do not change the class, but their risks belong in the risk assessment. If the main technical characteristic of the gateway were routing traffic between the plant network and the internet, it could have the core functionality of a class I router, regardless of the description in the manufacturer’s materials. The manufacturer compares its development process with IEC 62443-4-1 and fills the gaps shown in the mapping table in this article.

The product class decides the conformity assessment procedure

The CRA divides products into four groups. Annex III lists important products in classes I and II, and Annex IV lists critical products. The guidance calls all remaining products the default category. The Regulation does not use that name.

Product group Examples from the CRA annexes Procedure according to the guidance
Default category Products whose core functionality matches no category in Annexes III and IV. The manufacturer can always use the internal control procedure (module A), that is, self-assessment.
Important, class I Routers, modems intended for the connection to the internet and switches, operating systems, SIEM systems, products with a VPN function, password managers, microcontrollers with security-related functionalities. Internal control is possible after full application of a harmonised standard, a common specification or a European cybersecurity certification scheme at assurance level at least “substantial”. Otherwise a third party is required.
Important, class II Firewalls, intrusion detection and prevention systems, hypervisors, tamper-resistant microprocessors and microcontrollers. Third-party assessment is mandatory: module B+C, module H or a European certification scheme.
Critical Hardware devices with security boxes, smart meter gateways, smartcards and secure elements. Third-party assessment is mandatory: a European certification scheme and, where its conditions are not met, one of the class II procedures.

Important products of class I and II that qualify as free and open-source software placed on the market may follow the procedures of the default category. The Regulation sets one condition: the technical documentation is made publicly available when the product is placed on the market.

The detailed technical descriptions of the categories are in Commission Implementing Regulation (EU) 2025/2392 of 28 November 2025, and every product should be compared with them. The examples in the descriptions are illustrative and do not form an exhaustive list.

Core functionality and additional functions

What the guidance says. Core functionality means the main characteristics and technical capabilities without which the product cannot fulfil its intended purpose. It is assessed on the actual technical characteristics of the product. The instructions, sales materials and technical documentation help with the assessment, but a description that contradicts the technical characteristics does not change the result. A product has only one core functionality. The manufacturer describes it clearly in the technical documentation.

Additional functions do not change the class. A built-in component from an important or critical category does not by itself make the product important or critical. A manufacturer must not present the core functionality in a misleading way to avoid a stricter procedure. The guidance names clear inconsistencies between promotional materials, instructions for use and technical documentation as a warning sign.

Example from the guidance Product Commission’s conclusion
57 Software manages hardware, processes and memory and provides system interfaces to applications. The product has the core functionality of an operating system.
58 A smartphone contains an operating system. The smartphone serves communication and access to services, so it does not have the core functionality of an operating system.
59 A SOAR system can collect and correlate data like a SIEM, but its core includes incident response. The functionality of the SOAR clearly exceeds a SIEM, so a SOAR is generally not a SIEM system.
60 A tool collects logs and shows simple dashboards without correlation. The functionality of the tool falls short of a SIEM, so the tool is generally not a SIEM system.
61 A security suite combines a SIEM, an intrusion detection system and an analytics module, and the manufacturer also sells the modules separately. Each module is a separate product: the SIEM is class I, the intrusion detection system class II and the analytics module the default category.

OT products: core functionality first

Annexes III and IV and Regulation 2025/2392 do not list industrial control systems, PLCs and RTUs, SCADA and DCS systems or HMI panels. They contain no general category of gateways or IoT devices either. An OT product is therefore classified like any other: by its core functionality, not by its sector. Recitals 4 and 5 of Regulation 2025/2392 give two auxiliary rules. A router with a firewall function remains a router. A product that can perform the function of a category but has a different core functionality does not belong to that category.

The table below sets typical OT products against the annex entries as of 25 November 2026. The column with the interpretation is our assessment, because the Commission does not discuss these devices expressly.

OT product Annex entry and class Basis in the technical description Our interpretation
PLC, RTU or DCS controller No separate category, so usually the default category. No category description concerns process control. The controller stays in the default category even with a built-in firewall, a VPN client or a real-time system, because these are additional functions.
SCADA or HMI software No separate category, so usually the default category. No category description concerns supervision and visualisation of a process. A module also sold separately, for example a SIEM module for OT networks, should be classified separately by its core functionality.
Managed switch or industrial router Annex III, class I, point 12. The description covers switches with a management plane and wired and wireless routers. An industrial design does not change the category. A switch without a management plane does not meet the description of a switch in this entry.
Communication card or module with a fieldbus interface, sold as a separate product Annex III, class I, point 10. The description of physical network interfaces names, among others, Ethernet and fieldbus cards and adapters. A fieldbus port built into a controller does not make the controller a network interface, because integration alone does not change the class of a product.
Industrial firewall or an IDS or IPS system for OT networks Annex III, class II, point 2. The description covers network and application firewalls and intrusion detection and prevention systems. Inspection of industrial protocols does not change the core functionality. The assessment requires a third party.
VPN gateway for remote service Annex III, class I, point 5. The description covers VPN clients, servers and gateways. The category concerns a product whose core functionality is a VPN tunnel, not a device with a built-in VPN client.
OT network management system Annex III, class I, point 6. The description covers products that monitor network elements and control their configuration. This category fits a tool that configures switches and routers in a plant, not a SCADA system that only shows link status.
Real-time operating system sold as a product Annex III, class I, point 11. The description of operating systems includes real-time systems. A system embedded in a controller does not carry this class over to the controller, in the same way as the smartphone operating system in example 58.
Smart meter gateway Annex IV, point 2. The description covers gateways in smart metering systems under Directive (EU) 2019/944, also for gas and heat where the gateway meets the description. A gateway that collects data from sub-meters in a plant and does not work in such a metering system does not, in our assessment, belong to this category.
Hardware security module (HSM) Annex IV, point 1. The description of hardware devices with security boxes names HSMs. The category covers an HSM sold as a product, for example for signing firmware at the manufacturer.
TPM module or secure element Annex IV, point 3. The description of smartcards and secure elements names TPM modules. A TPM built into a controller does not make the controller a critical product.

The classification decides the conformity assessment procedure and the involvement of a notified body. This text is not legal advice, and it is worth consulting a lawyer before adopting a product class.

Decision table: product class and conformity assessment path

The table sets out the rules of Articles 7, 8 and 32 of the CRA and of Section 6 of the guidance in the order of checking. It is our summary, not a Commission table.

Step Question Answer YES: what next Answer NO: what next
1 Is the product subject to the CRA under the decision table in part 1? Go to step 2. No conformity assessment under the CRA is needed. Record the reasoning.
2 Has the manufacturer described one core functionality, in line with the actual technical characteristics of the product and consistently in the technical documentation, the instructions and the sales materials? Go to step 3. First determine the core functionality. Run modules that are also sold separately through the table separately.
3 Does the core functionality match the description of a category in Annex IV, as specified in Regulation 2025/2392? The product is critical. A European certificate is needed if a delegated act under Article 8(1) requires it. Otherwise the class II procedures apply. Go to step 4.
4 Does the core functionality match a class II category in Annex III? The assessment requires a third party: module B+C, module H or a European certification scheme at least at the “substantial” level. Go to step 5.
5 Does the core functionality match a class I category in Annex III? Go to step 6. The product belongs to the default category and may follow internal control (module A).
6 Has the manufacturer fully applied a harmonised standard referenced in the OJ, a common specification or a certification scheme at least at the “substantial” level, covering the risks of the core functionality? Internal control is possible. The manufacturer addresses the risks of additional functions by other measures and describes them in the documentation. The assessment requires a third party: module B+C or module H.

Important products of class I and II that are free and open-source software with public technical documentation may use the procedures of the default category in steps 4-6. In the sources checked on 25 November 2026 we found no delegated act under Article 8(1) that requires certification of critical products.

The IIoT gateway: class and evidence

Class. The manufacturer describes the BG-200 gateway from part 1 in all documents as a device for collecting and forwarding measurements, which matches its main technical characteristics. Steps 3-5 of the table give the answer NO, so in our assessment the gateway belongs to the default category. The packet firewall and the VPN client are additional functions, and the RS-485 port does not make the gateway a network interface. The manufacturer records this reasoning in the technical documentation and checks it again for firmware 4.0 from part 5.

Evidence. The list below is our proposal of evidence for the technical documentation of the gateway.

Requirement Evidence in the technical documentation of the BG-200 gateway
Risk assessment of the whole product The assessment covers the gateway, the service technician app, the RDPS services from part 3, the firewall, the VPN client and the open-source components.
Secure by default configuration A description of factory settings and a test confirming that the Wi-Fi access point works only in commissioning mode.
Security updates A description of firmware signing and a test in which the gateway rejects an image without a valid signature.
SBOM A machine-readable component list of firmware 3.2.1, with the TLS and MQTT libraries.
Coordinated vulnerability disclosure A published policy and an address for reporting vulnerabilities.
Effective and regular tests Penetration test reports for the gateway, the app and the cloud services, and a record of test reviews.
Support period The justification for 10 years and the place where the customer sees the end date of support at purchase.

Class I, harmonised standards and the presumption of conformity

An important product of class I may follow the internal control procedure when two conditions are met. The manufacturer applies all relevant requirements of a harmonised standard whose reference has been published in the Official Journal of the EU. The scope of that standard also covers at least all risks of the core functionality of the product.

A product is often broader than the standard. The manufacturer always carries out a risk assessment of the whole product. The risks of additional functions that the standard does not cover are addressed by other measures and described in the documentation.

Examples 62 and 63 from the guidance. An antivirus product also has disk cleaning and anti-tracking. A router has a built-in firewall. In both cases the manufacturer applies the standard to the core functionality and additional measures to the rest. It may therefore use internal control for the whole product. For the firewall in the router it may apply the harmonised standard for firewalls.

The presumption of conformity covers only the risks that the applied standard covers. In example 64, the antivirus product has the presumption of conformity for its core functionality, but not for the additional functions. In example 65, an updated standard also covers disk cleaning. The presumption then extends to that function, but still not to anti-tracking.

How to apply this. Before choosing the procedure, check whether the reference of the standard for the category is published in the Official Journal of the EU. Compare the scope of the standard with the list of product functions and record the gaps in the risk assessment.

State of harmonised standards as of 25 November 2026

The Commission addressed standardisation request M/606 to CEN, CENELEC and ETSI, adopted by Implementing Decision C(2025)618 of 3 February 2025. The request covers 41 standards. The horizontal standards concern requirements common to all products and vulnerability handling, and the vertical standards concern the categories in Annexes III and IV. The standardisation organisations accepted the request on 3 April 2025.

By Implementing Decision C(2026)7861 of 10 November 2026 the Commission changed the deadlines, after the standardisation organisations reported changes to the work schedule in their report of 3 June 2026. According to the Commission’s page, the extension is three months for all vertical standards and for some of the horizontal standards.

Standards from request M/606 Adoption deadline for the standardisation organisations after the change
Horizontal standard no. 1 on design, development and production with a level of cybersecurity appropriate to the risks 30 November 2026
Horizontal standard no. 15 on vulnerability handling 30 November 2026
Horizontal standards no. 2-14, one for each requirement of Annex I Part I point 2 30 October 2027
Vertical standards no. 16-41 for the categories in Annexes III and IV 31 January 2027

The decision ceases to apply if a standardisation organisation states, within one month of receiving it, that it does not accept the changes. The deadlines of the decision in the version of 3 February 2025 then apply.

The deadline in the decision concerns the adoption of a standard by the standardisation organisation. The presumption of conformity under Article 27(1) of the CRA arises only when the reference to the standard is published in the Official Journal of the EU. In the sources checked on 25 November 2026 we found no such publication for any standard under the CRA. A manufacturer of a class I product that plans internal control today should therefore also prepare a variant with module B+C or H, in case the references are not published before the product is placed on the market. The timetable on the Commission’s page, last updated on 27 July 2026, foresees a delegated act on the presumption of conformity for the European certification scheme EUCC in Q4 2026.

IEC 62443 and the presumption of conformity. No part of IEC 62443 is a harmonised standard under the CRA or has a reference in the Official Journal of the EU. An IEC 62443 certificate therefore does not give a presumption of conformity with the CRA. Only standards with a reference in the Official Journal, common specifications adopted by a Commission implementing act, and European certification schemes named in a delegated act give the presumption.

Secondary information, with a caveat. The German standardisation organisation DKE, in its list of CRA standardisation projects of November 2026, names the EN 50770 series “Security for Operational Technologies”. These are security profiles based on EN IEC 62443 for firewalls, IDS and IPS systems, network management systems, network interfaces, VPNs, routers, modems and switches, and SIEM. According to that list, all parts of the series are at the draft standard stage (prEN), that is, before the vote. The list names amendments to EN IEC 62443-4-1, 62443-4-2 and 62443-3-3 as supporting standards. This is a national source, and the state in the CEN and CENELEC databases may differ from it.

IEC 62443-4-1 and 62443-4-2 against Annex I: our analysis

An OT manufacturer that has implemented IEC 62443-4-1 and 62443-4-2 has to determine which CRA requirements it already meets and which it still has to add. The table below is our analysis, not the position of the Commission, ENISA or the standardisation organisations. We based it on the editions ANSI/ISA-62443-4-1-2018 and ANSI/ISA-62443-4-2-2018. The EN IEC editions may differ editorially, and amendments prepared for the CRA may change the result. We cite the requirements of the standards by number, without quoting their text.

In the coverage column, “full” means that the requirements of the standard cover the content of the CRA requirement, “partial” means that the manufacturer closes the gap by other means, and “none” means that the standard has no counterpart.

Annex I CRA requirement IEC 62443-4-1 IEC 62443-4-2 Coverage What must be added
Part I point 1: appropriate level of cybersecurity based on the risks SR-1, SR-2, SD-1, SD-2 SL-C levels as a target Partial The standard requires a threat model, but not a risk assessment of the scope in Article 13(2) and (3), with the intended purpose, reasonably foreseeable use and expected use time.
Part I point 2(a): no known exploitable vulnerabilities SVV-3, DM-3, DM-4 - Partial The standard allows a fix to be deferred and a risk to be accepted, but does not tie the assessment to the moment of placing the product on the market.
Part I point 2(b): secure by default configuration and reset SG-3 CR 7.6, CR 7.7 Partial We found no requirement in either standard to restore the product to its original state.
Part I point 2(c): updates, including automatic ones, with an opt-out SUM-1 to SUM-5 EDR, HDR and NDR 3.10 Partial Automatic updates by default, with an opt-out and postponement, are missing.
Part I point 2(d), (e), (f), (h), (j): access, confidentiality, integrity, availability, attack surface SD-1, SD-2, SI-2, SVV-3 Requirement families FR 1-4 and FR 7, for example CR 1.1, CR 3.4, CR 4.1, CR 7.1, CR 7.7 Full The technical requirements of the standard concern components of industrial control systems, so for other products the coverage has to be assessed separately.
Part I point 2(g): data minimisation - - None The standard does not regulate data minimisation.
Part I point 2(i): limiting the impact on other devices and networks - CR 7.1, CR 7.2 Partial The requirements mainly concern the resilience of the component itself. The standard does not expressly require limiting the impact on other devices and networks.
Part I point 2(k): limiting the impact of an incident SD-2, SI-2 SAR, EDR, HDR and NDR 3.2 Partial The standard does not require specific mechanisms for limiting the impact.
Part I point 2(l): logging and monitoring with an opt-out - CR 2.8 to CR 2.11, CR 6.1, CR 6.2 Partial The user’s ability to opt out is missing.
Part I point 2(m): erasure and transfer of data and settings SG-4 CR 4.2 Partial The standard describes erasing data when a component is decommissioned, but not easy erasure by the user or secure transfer.
Part II point 1: identification of components and SBOM SM-9, SM-10, DM-2, DM-3 CR 7.8 Partial A machine-readable SBOM covering at the very least the top-level dependencies is missing.
Part II point 2: addressing vulnerabilities without delay, separately from feature updates DM-4, SUM-1, SUM-5 - Partial The standard requires a policy on deadlines, but not addressing vulnerabilities without delay or separating security updates from feature updates.
Part II point 3: effective and regular tests and reviews SVV-1 to SVV-5, SI-1, SD-3, DM-6 - Full Add the review triggers for tests described in part 2 of the series.
Part II point 4: public disclosure of fixed vulnerabilities DM-5, SUM-2 - Partial The standard requires informing the users of the product, while the CRA requires public disclosure.
Part II points 5 and 6: CVD policy and a contact address for reporting vulnerabilities DM-1, DM-2 - Partial The standard requires a process for receiving reports, but not a published CVD policy and a public contact address.
Part II points 7 and 8: secure and automatic distribution, free of charge and without delay SUM-2 to SUM-5 EDR, HDR and NDR 3.10 Partial The standard requires the authenticity of patches, but not automatic distribution or free patches.

Some CRA obligations lie outside the scope of both standards: the support period and the availability of updates under Article 13(8) and (9), the end date of support stated at purchase, the reports under Article 14, the EU declaration of conformity and the CE marking, the instructions in Annex II and the technical documentation in Annex VII. The manufacturer meets them independently of IEC 62443. The JRC and ENISA report of 2024, still based on the draft CRA, reached a similar conclusion: no single standard covers all the requirements, and the EN IEC 62443 series covers many of them, but only for industrial control systems.

Risk assessment: an appropriate level instead of risk appetite

What the guidance says. In an organisation’s risk management, risk is compared with acceptance criteria derived from the risk appetite. According to the guidance, the CRA works differently. Residual risk is assessed by whether the product ensures an appropriate level of cybersecurity for its intended purpose and reasonably foreseeable use. The manufacturer’s internal risk tolerance, commercial strategy and costs alone are irrelevant here.

Residual risk cannot be removed completely. The manufacturer cannot, however, accept it at will. A product may be placed on the market when, after the measures have been applied, the residual risk has been sufficiently addressed by the essential requirements. The CRA does not allow transferring risk to the user or a third party to compensate for shortcomings in the design.

The manufacturer reduces risk in the product itself. The guidance lists example measures:

  • reducing the attack surface;
  • technical safeguards;
  • limiting or adapting functionality;
  • defining the intended purpose more precisely;
  • shaping use through risk communication, user guidance and interface design.

If these measures cannot reduce a risk, the manufacturer changes the design, the functionality or the intended purpose. Cost or commercial considerations alone do not justify leaving such a risk untreated.

Example 66 from the guidance. An industrial sensor has no protection against physical attacks because protection would interfere with correct operation. The manufacturer therefore limits the intended purpose of the sensor to trusted environments with controlled physical access and describes this limitation clearly in the instructions.

Example 67 from the guidance. A professional application stores sensitive data on managed devices. The manufacturer uses the encryption and key management of the operating system, which are mature and regularly maintained, and does not build its own mechanism.

How to apply this. Limiting the intended purpose is one of the measures named in the guidance. In our assessment it does not replace a safeguard that is technically possible and merely expensive, because according to the guidance cost alone does not justify leaving a risk untreated. Our OT example: a sensor must accept unencrypted frames from older controllers, so the manufacturer limits its intended purpose to a network zone without internet access. It describes this in the instructions and, in the sensor itself, disables by default the services that the sensor does not need.

The first essential requirement. Annex I requires that a product ensures an appropriate level of cybersecurity based on the risks. According to the guidance, this requirement covers the risks that the other essential requirements do not reduce. If the other requirements cover all risks, the first one is deemed fulfilled. This requirement differs from the obligation to carry out the risk assessment itself.

External dependencies and components

The CRA imposes two related obligations. The risk assessment covers risks from outside the product, for example from external networks, the environment and back-end systems. Due diligence concerns components from suppliers that are part of the product.

External dependencies. The manufacturer does not have to control the external environment. It reduces the resulting risk in the product. The guidance gives examples: cryptographic authentication of remote commands, integrity checks of configuration changes, and logs and alerts for unusual behaviour. The CRA may also require that the unavailability of an external service does not cause the product to enter an insecure state.

Components. The manufacturer determines what the product needs from a component, for example cryptographic functions, an update mechanism or secure communication. It then checks, in proportion to the risk, whether the component provides this. Evidence can be the supplier’s documentation: a specification, security documentation, or conformity or assurance documentation. Where needed, the manufacturer tests the component itself. A component that is covered by the CRA makes this easier, because the manufacturer can rely on the work of the component’s manufacturer.

The inventory of components is kept in an SBOM, that is, a software bill of materials. The CRA requires the SBOM to be in a commonly used and machine-readable format and to cover at the very least the top-level dependencies.

Product families

Variants, models and configurations of one family may share a risk assessment, the technical documentation and one conformity assessment procedure. The conditions are the same architecture, the same security solutions, the same intended purpose and the same risks. One EU declaration of conformity can then cover the group if it clearly identifies the variants.

Differences that matter for security are decisive. Colour, shape or memory capacity do not require a separate assessment. Different communication interfaces, a different software stack, a different update mechanism or remote connectivity must be considered in the risk assessment and, where necessary, in the conformity assessment.

Our example. A family of input and output modules has variants with 8, 16 and 32 channels, all with the same firmware and Ethernet port. They can share one assessment. A variant with a cellular modem and remote access requires an addition to the risk assessment.

Complex systems and older designs

Interoperability constraints. Complex systems, for example automation installations, have long cycles and must work with existing infrastructure. These characteristics do not exclude them from the CRA. When a requirement cannot be met because of the intended purpose or interoperability requirements, the manufacturer describes the constraint, assesses the risk and applies alternative or compensatory measures. It records them in the technical documentation and in the information for the user. It checks periodically whether the constraint still exists and, where possible, updates the product. The guidance notes that this rule may apply to any product.

Example 10 from the guidance. A product must work with systems that support only an older, less secure protocol. The manufacturer may implement that protocol for interoperability if it reduces its risk by other means. If the product can support both protocols, the secure protocol is implemented and enabled by default, and the older one is allowed only where interoperability requires it.

Our example. A controller must talk over Modbus TCP to existing SCADA systems. The manufacturer also implements Modbus/TCP Security or OPC UA with signing and encryption and makes them the default. Classic Modbus TCP is switched on deliberately in the configuration, and the instructions describe the required network zones and conduits and the risk. The principles of segmentation are described in IEC 62443 in practice.

Designs from before 11 December 2027. The manufacturer does not have to redesign a type designed earlier if the risk assessment shows that the existing safeguards are sufficient. The CRA does not require new security features where they are not needed. The manufacturer still carries out the conformity assessment, draws up the EU declaration of conformity and affixes the CE marking.

When the manufacturer cannot show how a risk assessment influenced the original design, it carries out a current risk assessment. On that basis it shows that the product has appropriate safeguards. It does not have to reconstruct historical design documentation or test results from earlier development phases. The guidance applies this relief in particular to products of the default category whose safeguards the risk assessment finds sufficient. The manufacturer may group the tests needed today across a product family. It must, however, demonstrate vulnerability handling, keep the risk assessment up to date and provide the information for the user.

Example 12 from the guidance. A microcontroller designed before 11 December 2027 is placed on the market after that date. The risk assessment covers unauthorised access, manipulation of software or data and misuse of interfaces. It shows that the original design addresses these risks appropriately. The manufacturer documents the current risk assessment, uses representative evidence for the family and maintains vulnerability handling. The microcontroller is placed on the market without redesign.

Example 11 describes a similar situation for components: the manufacturer of an automation system may use microcontrollers bought before 11 December 2027 if the risk assessment identifies no specific risks for them and the system as a whole meets the essential requirements.

Certificates under the RED and the Machinery Regulation

EU type-examination certificates and approval decisions issued under other legislation remain valid for cybersecurity requirements until 11 June 2028, unless they expire earlier or that other legislation provides otherwise. According to the guidance, the validity covers only the risks that this legislation covers. For those risks the manufacturer does not have to demonstrate conformity again for the CRA. Every product still needs a full risk assessment under the CRA, and the manufacturer addresses risks outside the certificate according to the CRA.

Basis of the certificate Risks the certificate may cover Risks the manufacturer still assesses under the CRA
Delegated Regulation (EU) 2022/30 under the Radio Equipment Directive (RED) Network protection, protection of personal data and privacy, and prevention of fraud, where the certificate covers them. The guidance names, for example, vulnerability handling processes, data minimisation and reduction of the attack surface.
Machinery Regulation (EU) 2023/1230, fully applicable from 20 January 2027 Protection against corruption and the safety and reliability of control systems, to the extent assessed in the certification. The manufacturer assesses additional cybersecurity risks that the certificate does not cover.

According to the guidance, a certificate that is valid longer under other legislation can be relied on for the purposes of the CRA only until 11 June 2028.

Checklist of evidence before the conformity assessment

  • The core functionality is described identically in the technical documentation, the instructions and the sales materials.
  • The product class has been compared with Annexes III and IV and with the technical descriptions in Implementing Regulation 2025/2392.
  • Modules sold separately have been classified separately.
  • The risk assessment covers the whole product, including additional functions, the RDPS and external dependencies.
  • The residual risk is justified by an appropriate level of cybersecurity, without reference to risk appetite or costs.
  • Limitations of the intended purpose are described in the instructions and justified by the function of the product.
  • For every component, the requirements of the product and the evidence that the component meets them are recorded.
  • The product family is described with a list of variants and an assessment of the differences that matter for security.
  • Interoperability constraints are described together with the compensatory measures and the date of their next review.
  • For older designs, a current risk assessment and evidence of vulnerability handling have been prepared.
  • Certificates under the RED and the Machinery Regulation have been matched to the risks they cover and to the date of 11 June 2028.

Where we help

We help manufacturers prepare the product risk assessment and the threat model according to IEC 62443-4-1, which feeds the technical documentation. Penetration tests of firmware, interfaces and industrial protocols provide evidence for the conformity assessment and for updating the risk assessment. During an IEC 62443 audit, we compare the development process with IEC 62443-4-1 and the technical requirements of components with IEC 62443-4-2. In large integration projects, our security architects support the product team with the architecture and the security documentation.

SEQRED is not a notified body, a conformity assessment laboratory or a certifier. A notified body carries out the conformity assessment in modules B+C and H, and the manufacturer draws up the EU declaration of conformity.

If you want to check whether your technical documentation has test evidence for every essential requirement, let us talk about the scope.

Topic Commission guidance C/2026/6013 Regulation (EU) 2024/2847
Important, critical and default category products points 136-138, footnotes 21-23 Article 7, Article 8, Article 32, Annexes III and IV
Core functionality points 139-146, examples 57-61 Article 7(1), Annex VII
Conformity assessment procedures and class I points 147-152, examples 62-63, footnotes 24-25 Article 32(2) to (5)
Presumption of conformity points 153-155, examples 64-65, footnotes 26-27 Article 27(1), (5), (8) and (9)
Classification of OT products points 139-145, example 58 Article 7(1), Article 8(1), Annexes III and IV, Implementing Regulation (EU) 2025/2392
Decision table for class and procedure points 136-152 Article 8(1), Article 32(1) to (5)
Harmonised standards and certification schemes points 148-155 Article 27(1), (8) and (9), Implementing Decisions C(2025)618 and C(2026)7861
IEC 62443 mapping to Annex I - Annex I Parts I and II
Risk assessment and mitigation points 156-163, examples 66-67 Article 13(2) and (3)
First essential requirement points 164-166 Annex I Part I point 1
External dependencies and due diligence point 120, points 167-173 Article 13(2) and (5), recital 34
SBOM - Annex I Part II point 1
Product families points 174-177 Article 13(2), Article 28
Complex systems and interoperability constraints points 29-32, examples 10-11, footnote 10 Article 13(3), recital 55
Designs from before 11.12.2027 points 33-39, example 12 Article 13(2), (3), (12) and (18), Article 32(1)
Certificates under the RED and the Machinery Regulation points 247-257, footnote 31 Article 69(1)

Sources

  1. Commission guidance on the application of Regulation (EU) 2024/2847 (Cyber Resilience Act), C/2026/6013 - European Commission, OJ C of 17.11.2026 - non-binding guidance, English text (accessed: )
  2. Regulation (EU) 2024/2847 on horizontal cybersecurity requirements for products with digital elements (Cyber Resilience Act) - EUR-Lex - English text of the Regulation, source of the terminology (accessed: )
  3. Regulation (EU) 2024/2847 on horizontal cybersecurity requirements for products with digital elements (Cyber Resilience Act) - EUR-Lex (accessed: )
  4. Commission Implementing Regulation (EU) 2025/2392 on the technical description of the categories of important and critical products with digital elements - EUR-Lex, OJ L of 1.12.2025 (accessed: )
  5. Cyber Resilience Act - Standardisation - European Commission, update of 23.11.2026 (accessed: )
  6. Commission Implementing Decision C(2026) 7861 amending Implementing Decision C(2025)618 (standardisation request, Regulation (EU) 2024/2847) - European Commission, 10.11.2026 (accessed: )
  7. Cyber Resilience Act: Standardization Request Officially Accepted by CEN, CENELEC, and ETSI - CEN-CENELEC (accessed: )
  8. Cyber Resilience Act - Implementation - European Commission (accessed: )
  9. CRA-Normungsprojekte - Status November 2026 - DKE (national German source) - secondary information relative to the CEN and CENELEC databases, German text (accessed: )
  10. Cyber Resilience Act Requirements Standards Mapping (EUR 31892 EN) - JRC and ENISA, 2024 - analysis based on the 2024 draft of the CRA; the report does not express the position of the Commission (accessed: )

Need help in this area?

Our experts will help you assess the risk and plan next steps.

Talk to an expert

We'll discuss scope, methodology, and timeline.

Book a call