OT Security
Security of SCADA, DCS and PLC industrial systems
We help industrial infrastructure operators secure their process networks, SCADA and DCS systems and PLCs. We work passively and plan every step with the maintenance team, so that production continuity is never put at risk.
What sets OT environments apart
- Availability and human safety
- In industrial systems the priority is process continuity and human safety, so we agree every step on the network with the maintenance team.
- Limited maintenance windows
- Changes are made within maintenance windows, and many systems cannot be easily updated. Security controls have to take this into account.
- Points of contact with IT
- Connections between corporate and industrial networks keep growing, including vendors' remote service access. We check these points of contact first.
- Passive work
- We carry out inventory and traffic analysis passively, and active tests on test devices, replicas or within agreed maintenance windows.
The four areas in OT environments
- Strategy and governance
A security programme that covers the industrial networks, with priorities and responsibilities agreed with the board and the maintenance department.
- Testing and audits
OT security assessment, IEC 62443 audit, penetration testing of industrial devices and protocols, and NIS2 audits that cover the process networks.
- Architecture and design
Dividing the OT network into zones and conduits in line with IEC 62443-3-2, and a security architect in modernisation and new-build projects.
- Implementation and support
Passive OT network monitoring, incident response plans with tabletop exercises for OT engineers, and industrial systems security training.
Services for OT environments
| Service | What it covers | Area | Engagement |
|---|---|---|---|
| vCISO | An experienced leader runs your security programme a few days a month. | Strategy and governance | ongoing |
| Penetration Testing | We show what an attacker could achieve through the flaws, and retest after your fixes. | Testing and audits | project |
| NIS2 Compliance Audit | We establish whether NIS2 applies to you and which security measures are still missing. | Testing and audits | project |
| IEC 62443 Audit | We establish the SL-A your zones and conduits achieve and what separates it from the SL-T. | Testing and audits | project |
| OT Security Assessment | We show which paths lead to your controllers and what to fix first. | Testing and audits | project |
| Security Architect | A senior expert reviews your projects and change requests within a monthly pool of hours. | Architecture and design | ongoing |
| OT Network Segmentation - Zones and Conduits | You get a network design you can roll out during maintenance windows. | Architecture and design | project |
| Incident Readiness | You get a response plan and playbooks tested with your team in a tabletop exercise. | Implementation and support | project |
| OT Network Monitoring | An alert flags a new device or unusual traffic, and the process runs undisturbed. | Implementation and support | project or ongoing |
| Cybersecurity Training | Each group gets its own programme, and we measure the effect, e.g. with simulated phishing. | Implementation and support | project |
Projects in OT environments
- Security audit of an energy operator's OT technology networkCritical energy infrastructure operator
- IEC 62443 audit of a new chemical plantEuropean chemical producer building a new polymer plant
- OT asset inventory and IEC 62443 audit of a DCSIndustrial manufacturing company
- OT security of a wind farmEuropean wind and solar farm operator
- Enhancing OT and IT Incident ResponseEuropean energy infrastructure operator
Why this matters - OT attacks in recent years
Industrial control systems have been the target of documented state-sponsored attacks. Each changed security assumptions in its industry.
- Stuxnet2010
The first known cyberweapon designed to physically damage industrial equipment. It destroyed uranium enrichment centrifuges at Iran's Natanz facility by manipulating Siemens S7 PLCs.
- Industroyer / Industroyer22016 / 2022
The first malware designed to attack electrical grids. Cut power in Kyiv; a follow-up targeted the Ukrainian grid in 2022.
- TRITON / TRISIS2017
Attack on a Safety Instrumented System at a petrochemical plant in Saudi Arabia. First malware to target SIS.
Frequently asked questions
Can work on the OT network disrupt production?
We use passive methods such as network traffic monitoring, agree every active step with the OT maintenance team and schedule it in a maintenance window.
Which OT platforms do you support?
We have experience with Siemens (SIMATIC, WinCC), Schneider Electric (EcoStruxure), Honeywell (Experion), Emerson (DeltaV), ABB, Allen-Bradley and others.
How does the collaboration with our OT maintenance team work?
We work closely with the client's automation engineers. Every step is consulted and planned around maintenance windows.
Where should OT security start?
Usually with an OT security assessment: an asset inventory and a review of the points of contact with the IT network. The results show whether segmentation, monitoring or an incident response plan is needed first.
Let's talk about the security of your industrial installation.
Book a call